GS100 & GS200

GS100 & GS200

Easy to Run, Ready for a Wide Range of Sequencing Needs

Product Highlights

Flexible Throughput for Diverse Use

With a broad output range from 25M to 400M reads, the GS Series enables flexible run configuration for different sample volumes and project needs.

Mixed-Library Sequencing in a Single Run

Sequence multiple application libraries together in one run, with real-time configuration to generate the read lengths required for different workflows.

High-Accuracy Sequencing Powered by Core Technologies

Built on the GS sequencing system, it integrates CYGNUS-developed LumoSeq and LoopChip technology to deliver high-quality, high-accuracy sequencing across diverse library types, without the need for additional balancing.

An Integrated Workflow from Sequencing to Insight

Paired with the CYGNUS X1 Bioinformatics System, the GS Series provides a streamlined end-to-end solution, covering the full workflow from sequencing to data analysis.

Performance Parameters

Instrument TypeEffective ReadsRead LengthsData outputRun TimeQ30Q40
GS100/GS200 25M SE100 2.5Gb 8hrs 95% 85%
PE150 7.5Gb 19.5hrs
50M SE100 5Gb 9.5hrs
PE150 15Gb 26hrs
PE300 30Gb 72hrs
100M SE50 5Gb 6.5hrs
SE100 10Gb 8.5hrs
PE100 20Gb 16.5hrs
PE150 30Gb 24hrs
GS200 200M SE50 10Gb 6.6hrs
SE100 20Gb 9.5hrs
PE100 40Gb 18.5hrs
PE150 60Gb 28hrs
400M SE50 20Gb 7.5hrs
SE100 40Gb 11.5hrs
PE100 80Gb 22hrs
PE150 120Gb 35hrs

Instrument Specifications

GS Series
Dimensions (W x D x H) 55cm x 65cm x 65cm
Package Dimensions (W x D x H) 67.6cm x 90cm x 98cm
Weight 90kg
Crated weight 165kg

Application Parameters

Estimated sample throughput for key applications

Application type25M50M100M200M400M
mNGS SE50 20M Reads 1 2 5 10 20
tNGS SE100 1M Reads 24 48 96 192 384
Targeted panel of tumor (tissue) PE150 1Gb/sample 7 14 30 60 120
Targeted panel of tumor (blood) PE150 6Gb/sample - 2 5 10 20
PGT-A SE100 3M/Reads 8 16 32 64 128
NIPT SE50 6M/Reads 4 8 16 32 64
WES PE150 15Gb/sample - 1 1-2 3-5 6-10

Ordering Information

Item NoNameinstrument
G-125-028-101 QF1C Reagent Kit (SE100) GS100/GS200
G-125-029-101 QF1C Reagent Kit (PE150) GS100/GS200
G-125-030-101 QF2C Reagent Kit (SE100) GS100/GS200
G-125-031-101 QF2C Reagent Kit (PE150) GS100/GS200
G-125-002-101 Q1C Reagent Kit (SE50) GS100/GS200
G-125-004-101 Q1C Reagent Kit (SE100) GS100/GS200
G-125-007-101 Q1C Reagent Kit (PE100) GS100/GS200
G-125-009-101 Q1C Reagent Kit (PE150) GS100/GS200
G-125-011-101 Q2C Reagent Kit (SE50) GS200
G-125-013-101 Q2C Reagent Kit (SE100) GS200
G-125-016-101 Q2C Reagent Kit (PE100) GS200
G-125-018-101 Q2C Reagent Kit (PE150) GS200
G-125-020-101 Q3C Reagent Kit (SE50) GS200
G-125-022-101 Q3C Reagent Kit (SE100) GS200
G-125-025-101 Q3C Reagent Kit (PE100) GS200
G-125-027-101 Q3C Reagent Kit (PE150) GS200

Resources

GS Series Brochure

Specifications, configurations and ordering information in one document.

Download

GS Series Publications

Research publications featuring GS Series sequencing systems across diverse applications.

Read

Technical Support

Expert support from application scientists, engineers and bioinformaticians across instrument operation, applications and data analysis.

Read